GeoTesting Express is a provider of Soil Testing Services – ASTM D, Standard Test Method for Unconsolidated-Undrained Triaxial Compression Test on. Buy ASTM D TEST METHOD FOR UNCONSOLIDATED- UNDRAINED TRIAXIAL COMPRESSION TEST ON COHESIVE SOILS. Standard Test Method for Unconsolidated – Undrained Triaxial Compression Test on Cohesive Soils.

Author: Takree Mataur
Country: Tanzania
Language: English (Spanish)
Genre: Marketing
Published (Last): 23 April 2007
Pages: 400
PDF File Size: 9.41 Mb
ePub File Size: 20.94 Mb
ISBN: 921-1-75683-864-7
Downloads: 21460
Price: Free* [*Free Regsitration Required]
Uploader: Gagis

Specimens are subjected to a confining fluid pressure in a triaxial chamber. In this system, the pound lbf represents a unit of force weightwhile the unit for mass is slugs. A typical Standard triaxial system with analogue measurements includes: Soil mechanics – Dynamic triaxial systems: Already Subscribed to this document. Soil testing Back to Results Print. The values given in parentheses are mathematical conversions to inch-pound units, which are provided for information only and are not considered standard.

The values stated in inch-pound units and given in parentheses are approximate.

Active view current version of standard. The failure envelopes will usually be a horizontal line sstm saturated specimens and a curved line for partially saturated specimens. Therefore, if several partially saturated specimens of the same material are tested at different confining stresses, they will not have the same unconsolidated-undrained shear strength. The specimen is sheared in compression without drainage at a constant rate of axial deformation strain controlled.

It is beyond the scope of this standard to consider significant digits used in analysis methods for engineering design.

ASTM D, Test equipment Controls

This test method provides for the measurement of the total stresses applied to the specimen, that is, the stresses are not corrected for pore-water pressure. Users of this test method are cautioned that compliance with Practice D does not ensure reliable results. We have no amendments or corrections for this standard. Need more than one copy? Can perform on up to 6″ diameter x 12″ high specimens.

  LX8384 DATASHEET PDF

This standard is not included in any packages. Soil testing Lab Services: The specimen is axially loaded at a constant rate of axial deformation strain controlled.

Iva Company info Privacy policy How one applies the results obtained using this standard satm beyond its scope. Historical Version s – view previous versions of standard.

ASTM D Standard

This test method provides for the measurement of the total stresses applied to the specimen, that is, the stresses are not corrected for pore-water pressure. Link to Active This link will always route to the current Active version of xstm standard. The determination of the consolidated, undrained strength of cohesive soils with pore pressure measurement is covered by Test Method D The specimen is sheared in compression without drainage at a constant rate of axial deformation strain controlled.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

You can download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked server. No drainage of the specimen is permitted during the test.

Agencies that meet the criteria of Practice D are generally considered capable of competent testing. The load frame is built around a robust twin column EmS technology is environmentally friendly and clean to operate, requiring no compressed air or hydraulic oil.

  KAZIMIERZ SIKORSKI HARMONIA PDF

ASTM D2850

In this test method, fluid flow is not permitted from or into the soil specimen as the load is applied, therefore the resulting d8250 pressure, and hence strength, differs from that developed in the case where drainage can occur. Standard triaxial configuration with external data acquisition can be used for performing additional test such as CBR, Unconfined and CRS, Permeability.

Referenced Documents purchase separately Aatm documents listed below are referenced within the subject standard but are not provided as part of the standard. Data are automatically transferred to the PC in real time for live plotting and monitoring of the tests in progress.

More than system configurations are available depending on type of test, sample size, pressure system. For Individuals with needing special assistance for disabilities or limited English dd2850 Please contact our Title VI specialist at TRITECH original high-performance load frames for triaxial tests, ideal solution for advanced and research laboratories that perform high quality tests at high productivity levels.

This standard is also available to be included in Standards Subscriptions. All the data acquisition and test management are made in manual mode Power supply is only required for air aetm and for triaxial load frame during failure stage.