ASTM E Is the American Society for Testing and Materials document titled, “ Standard Practice for Calculating Solar Reflectance Index of Horizontal and. ASTM Standards for Measuring Solar Reflectance and Infrared. Emittance of Construction Materials and Comparing their. Steady-State Surface Temperatures. 1, ASTM E specifications. 2. 3, Quantity, Name, Value, Units. 4, Solar reflectance of black surface, RB, 5, Solar reflectance of white surface, RW,

Author: Kagarisar Grosho
Country: Chad
Language: English (Spanish)
Genre: Travel
Published (Last): 8 May 2015
Pages: 166
PDF File Size: 7.76 Mb
ePub File Size: 20.80 Mb
ISBN: 503-3-18007-291-8
Downloads: 1181
Price: Free* [*Free Regsitration Required]
Uploader: Shaktinos

Legal information Privacy Policy Accessibility. Related Videos More videos.

ASTM E1980 – 11

Determination of solar reflectance and thermal emittance, and subsequent calculation of the relative temperature of the surfaces with respect to black and white reference temperature defined as Solar Reflectance Index, SRImay help designers and consumers to choose the proper materials to make their buildings and communities energy efficient.

Surface Optics does not perform aged SRI testing. The SRI value makes it possible for finishes to be categorised based on their capacity to reduce the urban heat island effect. Combined Sustainable Sites credits 7.

Our lab will provide a report that includes the values shown in Table 1 for the provided sample s. Many roofing manufacturers have already obtained independent laboratory testing of the SRI of their product catalog. The impact of hardscape such as roads, sidewalks, courtyards, and parking lots is an important element in earning the Heat Island reduction credit.

Green Building Council This accreditation is the result of a clear commitment to remain at the forefront of technical solutions in optical characterisation, and to provide such service for our customers.

  BARBARA ELSBORG FALLING FOR YOU PDF

To satisfy the requirements of the Heat Island reduction credits, a certain percentage of the hardscape and roofing must have a high solar reflectance index. No other units of measurement are included in this standard. Retrieved June 3,from http: By calculating the SRImanufacturers of building products are able improve the properties of the finishes, develop new products that comply with the requirements set out in the certification, and consequently, better position their products on the market.

Solar Reflectance Index Measurements – Surface Optics Corp.

Retrieved May 29,from http: For equivalent conditions, the lower the emissivity of a surface the higher its steady-state temperature. It is the responsibility of the user of e198 standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Table 2 shows the requirements for hardscape and shade providing architectural devices and structures. Surfaces with low solar reflectance, absorb a high fraction of the incoming solar energy.

Access to home page of website.

Astondo Bidea, Edificio Solar reflectance and thermal emittance are important factors affecting surface and near-surface ambient air temperature. Surfaces with low emissivity cannot effectively radiate to the sky and, therefore, astk hot.

The method is intended to calculate SRI for surfaces with emissivity greater than 0. Heat Island Effect — Non-Roof and 7. Link to Active This link will always route to the current Active version of the standard.

A fraction of this absorbed energy is conducted into ground and buildings, a fraction is convected to air leading to higher air temperaturesand a fraction is radiated to the sky. Jump to main contents of current page. Green Building CouncilOctober 4. Ed Bizkaia – Zamudio. Download PDF 8,49 Mb.

  EL ARTE DE INSULTAR SCHOPENHAUER PDF

The method described here gives the SRI of surfaces based on measured solar reflectances and thermal emissivities of the surfaces. Direct Normal and Hemispherical on 37 Tilted Surface. Go to main menu of page.

As a consequence, we strive to broaden the scope of accreditation year after year to include the new tests required in the industry. Da Vinci 11 Bizkaia – Zamudio. Through a system of international agreements, the results zstm by a laboratory accredited by ENAC are recognised in over 70 countries around the world.

The SRI makes it possible for finishes to be categorised based on their capacity to reduce the urban heat island effect. It is defined so that a standard black zstm reflectance 0. Heat island effect — roof. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. It also helps other agents such as architects, builders, and building f1980 and managers to choose suitable materials and finishes e1908 contribute to reducing surface temperatures, thereby reducing the energy consumption of the buildings.

Your desired roofing or hardscape SRI specifications may be readily available in the form of a manufacturer datasheet which can be used as LEED documentation. Historical Version s – view previous versions of standard.